| 2024/07/26 |
|
PCN(Product Change Notice)
|
Supplier Notice No.:NOE-24-026 Title: During qualification testing for a material change (pigment), some test articles failed to meet the requirements
Complaint Description:
During qualification testing for a material change (pigment), some test articles failed to meet the requirements of test groups V and VII when tested for Insulation Resistance after being exposed to Altitude Immersion and Moisture Resistance. The qualification of material change (pigment) for Shield Terminators included test group V (Altitude Immersion), VI (Temperature Cycling), VII (Moisture Resistance), VIII (Fluid Immersion) and IX (Heat Aging) in accordance with SAE AS83519. Test articles successfully met the requirements outlined for test groups VI, VIII and IX. All tested articles have passed Dielectric Withstanding Voltage. |
| 2024/10/04 |
|
PCN(Product Change Notice)
|
Supplier Notice No.:24-026 - Update Title: Notice of Escape 24-026 ? Update
Update Highlights: ? Qualification testing is complete ? Expected release of mil-spec parts: November 2024 ? Stop ship has been lifted for commercial part numbers
Description: Commercial parts are now available for shipment. Qualification testing is complete for M83519/1-1 through -5, and TE Connectivity (TE) submitted the attached Qualification Test Report (QTR) on September 30, 2024. We expect to receive approval from NAVAIR in November of this year. |
| 2025/01/15 |
|
PCN(Product Change Notice)
|
Updated document, Reason of update: Alert - TE Connectivity |