Output connection shape: Connector
1.5V or less
Number of output points: 32
Maximum load Resistive load: 0.1A/1 point
0.7W
External power supply: 5 to 30VDC
Open circuit leakage current: 0.1mA or less/30VDC
Relay output
Sink/Source
50|60Hz
I/O control method: batch processing method (when END instruction is executed), I/O refresh instruction, pulse catch function
Programming language: Relay symbol method + step ladder method (SFC expression possible)
Number of input points:40
50W This is the value when the 24VDC service power supply of the basic unit is consumed at maximum by the additional input/output expansion block or special expansion unit/block.
Number of output points:40
Arithmetic control method: Stored program repetitive operation method (dedicated LSI), with interrupt function
Maximum memory capacity: 64000 steps including comments and file registers
100 to 240V
Input/output control method: Refresh method (direct access input/output possible by specifying direct access input/output (DX, DY))
Built-in analog input: 2ch
Built-in analog output: 1ch
Built-in high-speed counter: max. 6ch 200kHz + 2ch 10kHz
Built-in Ethernet port: 1ch
Built-in RS-485 port: 1ch
AC power DC input Screw terminal block type
16 points 24VDC Sink/Source
Stored program iteration operation
16 points Relay
5VDC internal current consumption:0.34A
16 points (I/O allocation: Intelli 16 points)
Analog output points: 4 points (4 channels)
Conversion speed:80us/1channel
Input (resolution):0 to 4000,-4000 to 4000,0 to 12000,-12000 to 12000,-16000 to 16000
DC-10 to 10VDC|DC0 to 20mA
External wiring connection method: 18-point screw terminal block (M3 screw)
Internal Current Consumption(DC5V):0.58A
32 points (I/O allocation: Intelli 32 points)
Software: Data logging function/event logging function/report function/recipe function
10BASE-T/100BASE-TX:1channel
4096
Program capacity:40K step
Basic instruction processing time(LD X0):0.98ns
Peripheral device connection ports: USB, Ethernet CC-Link IE built-in
160kB
Output common method: 16 points, 1 common
5VDC:140mA(TYP. All ON)
16 points (I/O allocation: 16 outputs)
1ms
Transistor output: 16 points DC12/24V 0.5A/1 point, 5A/1 common (sink type)
External wiring connection method: 18-point screw terminal block (M3 screw)
Output common method: 32 points, 1 common
5VDC:180mA(TYP. allON)
32 points (I/O allocation: 32 outputs)
1ms
Transistor output: 32 points, 12/24V DC, 0.2A/1 point, 2A/1 common (sink type)
External wiring connection method: 40-pin connector
ECCN: EAR99
CJ1WTC002
Memory backup battery for FX2N
CE(Battery)
Expansion block, extension cable for expansion unit
0.65m
Relay
Sink
Number of input points:4
Input connection shape: Vertical terminal block (M3 screw)
Number of output points:4
Output connection shape: Vertical terminal block (M3 screw)
Maximum load Resistive load: 2A/1 point
Input signal format: No-voltage contact input NPN or open collector transistor
Sink
Number of input points: 16
Input connection shape: Connector
Input signal current: 5mA/24VDC
2.2W
No-voltage contact input or NPN open collector transistor
Input signal voltage: 24V +20% -15% Ripple (p-p) within 5
Output connection shape: Connector
1.5V or less
Number of output points: 16
Maximum load Resistive load: 0.1A/1 point
0.35W
External power supply: 5 to 30VDC
Open circuit leakage current: 0.1mA or less/30VDC
0 point (not related to the maximum number of input/output points of the sequencer)
Analog output range: Voltage output: 0V to 10V DC (external load resistance 2kΩ to 1MΩ) Current output: 4mA to 20mA DC (external load resistance 500Ω or less)
Applicable sequencer: FX3S, FX3G (V1.10 or later) When FX3S is connected, the function expansion board and FX3S-CNV-ADP cannot be used together.
D/A conversion time: 60us (data is updated every operation cycle)
Isolation method: Non-isolation between analog input and sequencer, and between each channel
Number of output channels: 1 channel
Relay output
Sink/Source
50|60Hz
I/O control method: batch processing method (when END instruction is executed), I/O refresh instruction, pulse catch function
Programming language: Relay symbol method + step ladder method (SFC expression possible)
Number of input points:24
37W
Number of output points:16
Arithmetic control method: Stored program repetitive operation method, with interrupt instructions
Maximum memory capacity: 32000 steps 32000 steps including comment and file registers
100 to 240V
Relay output
Sink/Source
50|60Hz
I/O control method: batch processing method (when END instruction is executed), I/O refresh instruction, pulse catch function
Programming language: Relay symbol method + step ladder method (SFC expression possible)
Number of input points:8
30W
Number of output points:8
Arithmetic control method: Stored program repetitive operation method (dedicated LSI), with interrupt function
Maximum memory capacity: 64000 steps including comments and file registers
100 to 240V
Memory backup battery for FX5U, FX5UC, FX3G, FX3U, FX3GC, FX3UC, IU2-3M10, IU2-1EMES-100M